Search results for "high resolution"
showing 10 items of 249 documents
High resolution study of the 3ν1 band of SO2
2009
Abstract The second overtone band 3 ν 1 of sulfur dioxide has been studied for the first time with high resolution rotation-vibration spectroscopy. About 3000 transitions involving about 900 upper state energy levels with J max. = 66 and K a max. = 24 have been assigned to the 3 ν 1 band. In the analysis, an effective Hamiltonian taking into account accidental interactions between the vibrational states (3 0 0), (2 2 0), and (0 4 1) was used. The Watson operator in A -reduction and I r representation was used in the diagonal blocks of the Hamiltonian. As the result of analysis a set of parameters reproducing the initial experimental data with the rms = 0.00028 cm −1 was obtained.
2011
High Resolution CT Angiography in Detection of an Aneurysm of the Vein of Galen as a Source of Intracranial Haemorrhage in a Newborn.
2011
Cerebral haemorrhage is a rare condition in infants and carries a known poor prognosis. Common causes of spontaneous haemorrhage include various vascular venous lesions due to incomplete hydrovenous maturation, among them Galen vein aneurysm may be a very rare cause of cerebral haemorrhage. This report emphasizes the role of multidector CT with high resolution CT angiography in a newborn with cerebral hemorrhage caused by Galen vein aneurysm rupture. MDCT with high resolution CT angiography helps to differentiate the cause of haemorrhage, and to address the appropriate treatment.
High resolution Time of Flight determination based on reconfigurable logic devices for future PET/MR systems
2013
Abstract This contribution shows how to perform Time of Flight (TOF) measurements in PET systems using low-cost Field Programmable Gate Array (FPGA) devices with a resolution better of 100 ps. This is achieved with a proper management of the FPGA internal resources and with an extremely careful device calibration process including both temperature and voltage compensation. Preliminary results are reported.
Identification of a novel mutation in the alpha-galactosidase A gene in patients with Fabry disease.
2012
Abstract Objectives Mutation analysis of the alpha-galactosidase A (GLA) gene is a valuable tool for the diagnosis of affected families. In our work, we analyze about one thousand samples per year from patients suspected of having Fabry disease (FD). Design and methods We carried out high resolution melting analysis (HRM) and DNA sequencing of all the exons of the GLA gene. We also assayed the alpha-galactosidase A activity in patients' blood. Results In some members of one family, we identified a new mutation in the GLA gene, c.614delC. This is a deletion of a single nucleotide, a cytosine, in exon 4 of the gene which causes a frameshift mutation. Conclusions Patients with the c.614delC mu…
Was heißt wie? Ansatz und Glossar zu Befundung und Verständnis in der HRCT der Lunge
1996
In HRCT reports multiple different, often synonymous, German and English terms are used. The variety of terms impede understanding and acceptance of HRCT. Purpose of this paper is to present a scheme, which is based on the anatomic landmarks (secondary lobule), and the density of pathologic changes, as well as a glossary from the German HRCT-literature, including suitable terms, definitions, synonyms and English terms. Low attenuation changes include emphysemas, air-filled cavities (bullae, cysts, cavitations, honeycombing) and bronchial dilatation, changes with increased density consist of diffuse (ground glass opacity, consolidation) and focal processes (reticular and nodular densities). …
Size Exclusion Chromatography of Proteins on Improved Bonded Silica Columns
1985
Publisher Summary This chapter discusses the size exclusion chromatography (SEC) of proteins on improved bonded silica columns. Over the past few years, the use of high performance liquid chromatography (HPLC) has been extended to protein chemistry as a powerful separation and isolation technique. A spectrum of variants providing high resolution potential—ion exchange, reversed phase, hydrophobic interaction, affinity, and size exclusion—is available. Of these, SEC is the simplest with respect to method development and equipment design: proteins are separated according to their size in a short and predictable time span under isocratic conditions. The SEC columns are packed with micro-partic…
32×32 winner-take-all matrix with single winner selection
2010
A 32 × 32 winner-take-all (WTA) matrix with single winner selection is introduced. A high-resolution gain-boosted regulated-cascode WTA circuit is used in a first competition stage. Because of the large number of competing cells the possibility of a multiple winners situation arises. A single winner is obtained by means of a digital inhibitory circuit following each WTA analogue amplifier. Simulations show that this mixed analogue-digital circuit achieves its objective with a current resolution of approximately 10 nA (0.8% of the maximum input current in the simulated case). A time response of ?s can be achieved.
Ultrahigh-Resolution Microwave Spectroscopy on TrappedYb+171Ions
1982
Determining seasonality of mussel collection from an early historic Inuit site, Labrador, Canada: Comparing thin-sections with high-resolution stable…
2018
International audience; Stable oxygen isotope (delta O-18) analysis of mussels (Mytilus sp.) from a 16th to mid-18th century Inuit site in southern Labrador, Canada, indicates multiple seasons of shellfish collection, and by proxy, multiple seasons of site occupation. High-resolution delta O-18 sampling of shell permits a precise season of mussel collection since the temperature and freshwater signal of the local water is retained in the shell. Live-collected specimens of Mytilus sp. obtained from Labrador, were analyzed for stable oxygen isotopes and for growth patterns. These data were used to interpret results from the archaeological shells. Growth pattern analysis was conducted to test …